Produse pentru oscilator electric (1)

Orificiu Integrat

Orificiu Integrat

Complete measuring element with special flanges - Suitable for pipe diameters ≤ 40 mmInstallation of the integrated sharp-edge orifice plate: between special flanges (direct mounting of the manifold and the differential pressure transmitter) Solder (BW) or flanged connection Material: Standard: carbon steel, stainless steel, others according to your application. Standards:ASME MFC-14M Fluid:liquid, gas, steam Diameter of pipes:from 6 to 40 mm Overall measurement accuracy:0.5% of max flow Repeatability of the measure:0.1% Reynolds number in pipework:ReD > 1 000 Pipe interior diameter:6 mm ≤ D ≤ 40 mm d/D:0.1 ≤ β ≤ 0.8 Roughness of the upstream face plate:Ra <1.27 μm Sharp edge radius:r <0.000 4.d or (1) 0.025 μm Orifice thickness:e < 0.02.D or (1) 0.125.d Plate tickness:E < 3,2 mm Downstream bevel angel:α = 45 ° ± 15 ° Flatness tolerance:t < 0,01.(D - d)/2